Skip to content
CO2 - Samushao sivrceshi

What Is the Acceptable Level of Carbon Dioxide (CO₂) in the Workplace, and Why Is Continuous Monitoring Important?!

Carbon dioxide, also known as carbon dioxide gas, CO2 and oxide C(IV), is the highest oxide of carbon. Carbon dioxide makes up 0.03% of the air. It is a colorless gas with a slightly acidic smell and taste, with a density of 1.9 kg/m3.

Continuous exposure to excessive amounts of carbon dioxide in the air, meaning concentrations of 2000 ppm or higher, may cause symptoms such as headaches, sweating, and shortness of breath. It is also known that high concentrations of CO2 in the workplace increase the risk of viral disease transmission.

The following main factors determine the amount of CO2 in a building:

      • – The number of people inside the building;
      • – Building characteristics (e.g., the materials used for interior finishes, how long the building has been in operation, etc.);
      • – The volume of fresh air entering from outside;
      • – The volume of spaces or rooms;
      • – Whether combustion by-products pollute the indoor air (e.g., vehicles and machinery, furnaces, tobacco smoke, etc.);
      • – The concentration in the outdoor air.

 

Since carbon dioxide is a natural by-product of human respiration, people occupying indoor spaces are its primary source. Therefore, as already mentioned, high concentrations of CO2 in workplaces can be used as an indicator of the number of employees and the ventilation rate.

Good ventilation in indoor spaces is a crucial factor in reducing the spread of viral infections through airborne transmission. For this very reason, a campaign is underway across the United Kingdom to monitor CO2 levels in classrooms in order to reduce the risk of viral disease transmission.

What CO2 levels are acceptable in buildings?

Acceptable levels of CO2 generally vary from country to country.

For example, in the United Kingdom, the government has agreed on a set of standards for acceptable indoor CO2 levels, namely:

  • 800 ppm or below indicates that the indoor space is well ventilated and the indoor air quality is acceptable.
  • 1500 ppm and above indicates that the room is poorly ventilated. In such cases, appropriate recommendations and measures should be implemented to improve ventilation.

Recommendations vary. For example, in the United States, the Occupational Safety and Health Administration (OSHA), part of the Department of Labor, has established 5000 ppm as the permissible exposure limit for CO2, expressed as an 8-hour time-weighted average. Meanwhile, according to the American Society of Heating, Refrigerating and Air-Conditioning Engineers (ASHRAE), indoor carbon dioxide levels should be below 700 ppm.

Many countries, including Japan, Korea, Portugal, France, and Norway, have established 1000 ppm as the CO2 standard for specific indoor spaces, including schools and office buildings.

Guidelines on indoor air pollution caused by carbon dioxide are generally provided as recommendations rather than legally enforceable requirements. However, in the United Kingdom, employers remain responsible for protecting the safety of their employees, including ensuring appropriate carbon dioxide levels in office buildings. As a result, monitoring CO2 levels became mandatory in all office buildings from June 2022. New standards for recirculating ventilation were also introduced. All of the above forms part of the latest amendments to building standards and regulations aimed at improving ventilation and air quality in commercial and residential buildings.

According to Government of Georgia Resolution No. 69, adopted on January 15, 2014, air quality monitoring in industrial workplaces in Georgia covers only air and surface temperatures, humidity, and air velocity. Standards for carbon dioxide concentrations in the air or air exchange rates have not been established, even in the form of recommendations. Nevertheless, there is a company in Georgia that leads not only in Georgia but also among the world's leading countries in implementing the highest standards for workplace conditions, including, but not limited to, air quality management, lighting, and workplace ergonomics.

We would like to introduce our partner organization, “Aviator” LLC (“Adjarabet”), whose policy is to ensure that employees work in a safe microclimate to the greatest extent possible. The company has implemented continuous air quality monitoring using the latest modern equipment and software, including permanent monitoring of airborne CO2 concentrations.

It is also worth noting that air recirculation is not used in Aviator's office to ensure complete air exchange (the entire building's air is replaced four times per hour). To minimize energy losses, all air handling units (AHUs – Air Handling Units) are equipped with highly efficient heat recovery systems.

It is worth emphasizing that the above-mentioned systems at Aviator entered operation in December 2021.

As explained by the company's engineering representative, CO2 (PPM) measuring sensors are installed in the air extraction systems to analyze carbon dioxide concentrations in the air in real time. Based on the information obtained, air exchange is regulated in specific areas. If a sensor in any area becomes damaged, the software detects the issue and displays a corresponding notification on the control panel.

The accepted air exchange standard in European countries is 35–40 m3 per person, while in the high-tech office of “Aviator”, the average air exchange rate is 60 m3 per person (with a maximum supply volume of 90 m3, when required). This is the result of the high standards required by the employer when planning the workplace. This is made possible by the flexibility of the ventilation system, which allows air at the desired temperature to be supplied to the workplace at any time of the year (within a range of 16–28oC). In addition, indoor air temperature can be adjusted using Mitsubishi City Multi II VRV system units.

At present, airborne carbon dioxide concentrations in Aviator's indoor workspaces range from 500 to 600 ppm, which is significantly below the standard established in the United Kingdom (800 ppm)!

The occupational health and safety training provider and consulting company “SafCo” welcomes this important initiative by its partner company “Aviator” and encourages both commercial and public sector organizations to adopt the best practices implemented by “Aviator” in their own workplaces.

 

SafCo wishes you health and safety!